Key Features
Highly poison-resistant catalytic bead combustible gas LEL sensor
4 to 20mA analog and RS-485 digital output of 0 to 100%LEL combustible gas including methane, hydrogen or other combustible gases
Explosion-proof enclosure for hazardous environment applications
Local displays with adjustment keys
Non-intrusive calibration
Magnetic key interface eliminates need to open explosion-proof housing when making calibrations or other minor adjustments
Operation at 9 to 36 VDC
Dry-contact output (<30V, 2A)
Hazardous Location Classification UL: Class I, Division 1, Groups B, C, D
Temperature Code T6
Chinese Certificate: Ex d IICT6 |